Differences
This shows you the differences between two versions of the page.
| Both sides previous revision Previous revision Next revision | Previous revision | ||
| iop_correction_corneal_thickness [2026/09/14 16:11] – Scott Larson | iop_correction_corneal_thickness [2026/09/14 16:19] (current) – Scott Larson | ||
|---|---|---|---|
| Line 1: | Line 1: | ||
| ====== IOP correction for Central Corneal Thickness ====== | ====== IOP correction for Central Corneal Thickness ====== | ||
| + | These data were collected in adults and may not apply to children. | ||
| ^ Central Corneal Thickness (μm) ^ Correction Value (mmHg) | ^ Central Corneal Thickness (μm) ^ Correction Value (mmHg) | ||
| | 410 | +10 | | | 410 | +10 | | ||
| Line 32: | Line 32: | ||
| ====Derived Formula==== | ====Derived Formula==== | ||
| - | \text{Corrected IOP} = \text{Measured IOP} - \frac{(\text{CCT} - 545)}{50} \times 2.5 \text{ mmHg} | + | $$ \text{Corrected IOP} = \text{Measured IOP} - \frac{(\text{CCT} - 545)}{50} \times 2.5 \text{ mmHg} $$ |
| ===== References ===== | ===== References ===== | ||
| - | [[https:// | + | - [[https:// |
| + | - [[https:// | ||
| {{tag> | {{tag> | ||